5069 if8 manual - Catalog Numbers 5069-IB8S, 5069-IB8SK The 5069-IB8S and 5069-IB8SK modules are 8-point safety sinking input modules. The modules provide safety I/O on a safety-control network that meets the requirements up to and including SIL CL 3, and PLe, Cat. 4 as defined in IEC 61508, IEC 61511, IEC 62061, and ISO 13849-1.

 
View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Important User Information Read this document and the documents listed in the additional resources section about... . Strongest thc o flower

DDS• The 5069-IA16 module inputs use a shared common. The inputs have a return through internal module circuitry to the SA (–) terminal on the SA Power RTB. • If you install modules in a 5069 Compact I/O system that use AC SA power and DC SA power, you must install them on separate SA Power buses.Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User InformationControlLogix 8 Point A/I Module. Lifecycle status: ACTIVE. Find a Distributor. Find Product Drawings. Find Firmware & Downloads. Add to BoM. Get Support. 1756-IF8. Find a Distributor.5069 Compact I/O 16 Channel 24VDC Sink Input Module. Lifecycle status: ACTIVE. Find a Distributor. Learn how to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Add to BoM. Get Support. 5069-IB16. Find a Distributor.Sep 26, 2022 · 5069-IF8 FieldPowerOff = 1. Got a trouble call with a 5069-IF8 module that has all the channels flashing red. Upon logging in, I see that each channel is faulted with the FieldPowerOff bit set to 1. I had them verify the SA power is good, which it is, and another 5069-IF8 module 2 slots down is functioning fine, so SA power appears to be good. Technical Data. 5069-TD001. Find more technical documentation for this product in the Technical Documentation Center. TYPE. Technical Data. PUBLICATION NUMBER. 5069-TD001.Module, Distributed I/O, 8 Channel, Analog Input, HART. Lifecycle status: ACTIVE. Find a Distributor. to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Register this Product. Add to BoM. Get Support. 5094-IF8IH. 1 Publication 1769-UM002B-EN-P - July 2005 Summary of Changes The 1769-IF8, -OF8C, and -OF8V modules have been added to this manual since the last printing.1 Publication 1769-UM002B-EN-P - July 2005 Summary of Changes The 1769-IF8, -OF8C, and -OF8V modules have been added to this manual since the last printing. Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available. These modules are the ideal ... Allen-Bradley 5069-IF8 User Manual Download Operation & user’s manual of Allen-Bradley 5069-IF8 I/O Systems for Free or View it Online on All-Guides.com. This version of Allen-Bradley 5069-IF8 Manual compatible with such list of devices, as: 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8Catalog Numbers 5069-AENTR, 5069-AENTRK, 5069-AEN2TR The Compact 5000™ I/O EtherNet/IP adapters perform the following functions: • Facilitate high-speed data transfer across an EtherNet/IP network between Compact 5000 I/O modules and a Logix 5000™controller. • Provide system-side and field-side power to Compact 5000 I/O modules. Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available. These modules are the ideal ...Get Support 5069-IF8 Find a Distributor Technical Specifications For full product specifications, please see the product catalog. Documentation Find all available product literature for this product in the Literature Library results. 1 Publication 1769-UM002B-EN-P - July 2005 Summary of Changes The 1769-IF8, -OF8C, and -OF8V modules have been added to this manual since the last printing. Lifecycle status: ACTIVE. Find a Distributor. to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Register this Product. Add to BoM. Add to Repair Quote. Get Support. 5069-L320ER.Issue 3: Updated ratings on 5069-IB6F3W and 5069-OF8 to 900mA and 250mA respectively, added models 5069-IA16, 5069-OB8, 5069- OA16 and 5069-OW16 and updated drawings. Issue 4: Update was to clarify the spacings verdict in Clause 13 from the IEC 60079-15 standard.The Allen-Bradley 5069 Compact 5000 series 5069-IF8 module is an analog input module. It is an 8-channel current/voltage input module. It offers differential, non-isolated inputs that are able to connect with different input devices. The module comes with 16-bit resolution and it has an update time of 1 millisecond.Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available. These modules are the ideal ...2 Rockwell Automation Publication 5069-TD001D-EN-P - October 2016 5069 Compact I/O Modules Specifications Summary of Changes Changes to the publication are listed in this table. Digital I/O Modules Topic Page Addition of information for the 5069-IA16 digital input module 3 Addition of information for the 5069-OA16 digital output module 18 5069-IF8: Manufacturer: Allen-Bradley / Rockwell Automation: Description: Allen-Bradley 5069-IF8 5069 Compact I/O 8-Ch Current/Voltage Input Module: Full Description: Allen Bradley 5069-IF8 5069 CompactLogix Compact I/O 8 Channel Current/Voltage Analog Input Module: UPC / GTIN: 00885630530062: Status: Current ProductView and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Important User Information Read this document and the documents listed in the additional resources section about...Access technical specifications, installation instructions, and manuals for Allen-Bradley 5069 Compact 5000 I/O and chassis-based communication modules.ControlLogix 8 Point A/I Module. Lifecycle status: ACTIVE. Find a Distributor. Find Product Drawings. Find Firmware & Downloads. Add to BoM. Get Support. 1756-IF8. Find a Distributor.Catalog Number 5069-OA16 The 5069-OA16 digital 16-point AC output module supports 120V AC and 240V AC signals drive output devices. The data that is sent to the module from a controller and the state of some input modules determines the 5069-OA16 module behavior. Compact 5000™ I/O modules use the Producer/Consumer communication model. Literature Library | Rockwell AutomationUser ManualOriginal Instructions Compact 5000 I/O Analog Modules Catalog Numbers 5069-IF8, 5069-IY4, 5069-IY4K, 5069-OF4, 5069-OF4K, 5069-OF8 2Rockwell Automation Publication 5069-UM005C-EN-P - January 2022 Compact 5000 I/O Analog Modules User Manual Important User Information View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 27 - Module (MOD) Status Indicator - 5069 Compact I/O Analog I/O Modules...May 7, 2022 · The 5069 analog I/O modules for use with this controller are 5069-IF8 (differential current/voltage) and 5069-IY4. The IY4 is able to take thermocouple and RTD inputs along with diff current and voltage. The user manual ( Compact 5000 I/O Analog Modules User Manual) for both of these modules state that 3-wire analog devices " are not supported ... The 5069-FPD field potential distributor breaks field-side power distribution in a CompactLogix™ 5380, CompactLogix 5480, or Compact GuardLogix® 5380 control system or a Compact 5000™ I/O system and creates a new SA power bus to the right of the field potential distributor from which Compact 5000 I/O modules can draw current. 1746-to-5069 I/O Conversion System Installation ... 1746-NO4V 4-Channel Analog I/O Modules User Manual Download. 1746-NI8 Analog Input Module User Manual I saw this thread and thought "there's no way in the world a 5069-IF8 doesn't support 3 wire transmitters" and figured I'd find a working example onsite to prove it, then post back. I then promptly forgot about it. But I remembered this morning, and yes, I have wired 2, 3 and 4 wire 4-20mA transmitters to a 5069-IF8 and it works just fine.View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 27 - Module (MOD) Status Indicator - 5069 Compact I/O Analog I/O Modules... This manual describes how to install, configure, and troubleshoot your ControlLogix® digital I/O modules. There is also a complete listing of digital input and output modules, including specifications and wiring diagrams. You must be able to program and operate a ControlLogix controller to use your digital I/O module efficiently.5069-L310ERS2K, 5069-L310ERMS2K, 5069-L320ERS2K, 5069-L320ERMS2K, 5069-L330ERS2K, 5069-L330ERMS2K, 5069-L350ERS2K, 5069-L350ERMS2K Compact GuardLogix 5380 SIL 3 Controller Catalog Numbers 5069-L306ERMS3, 5069-L310ERMS3, 5069-L320ERMS3, 5069-L330ERMS3, 5069-L340ERMS3, 5069-L350ERMS3, 5069-L380ERMS3, 5069-L3100ERMS3 Compact GuardLogix 5380 SIL 3User Manuals, Guides and Specifications for your Allen-Bradley 5069-IF8 I/O Systems. Database contains 1 Allen-Bradley 5069-IF8 Manuals (available for free online viewing or downloading in PDF): Operation & user’s manual .The 5069-IY4 has an input resolution of 15-bits plus sign and 16 bits for voltage; 16-bits for current, RTD and Thermocouple. Is the Thermocouple input provided with CJC sensors? Yes. Two (2) CJC sensors are available. What is the scan time of the 5069-IY4? The 5069-IY4 has rated scan time of 625 µs per channel and 2.5 ms per group.Use your product. Compact I/O ASCII Module User Manual Compact I/O BOOLEAN Module User Manual Compact I/O BOOLEAN Module Reference Manual Compact High-speed Counter Module User Manual 1769-IR6 RTD/Resistance Input Module User Manual 1769-IT6 Thermocouple/mV Input Module User Manual.5069-IF8: Manufacturer: Allen-Bradley / Rockwell Automation: Description: Allen-Bradley 5069-IF8 5069 Compact I/O 8-Ch Current/Voltage Input Module: Full Description: Allen Bradley 5069-IF8 5069 CompactLogix Compact I/O 8 Channel Current/Voltage Analog Input Module: UPC / GTIN: 00885630530062: Status: Current Product Literature Library | Rockwell AutomationView and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 27 - Module (MOD) Status Indicator - 5069 Compact I/O Analog I/O Modules...Access technical specifications, installation instructions, and manuals for Allen-Bradley 5069 Compact 5000 I/O and chassis-based communication modules.Summary of Contents for Allen-Bradley 5069-IF8. Page 1 User Manual 5000 Series Analog I/O Modules in Logix5000 Control Systems Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8... Page 2 Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE). Allen-Bradley, Compact I/O, ControlLogix, Integrated ...View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 27 - Module (MOD) Status Indicator - 5069 Compact I/O Analog I/O Modules...2 Rockwell Automation Publication 5069-IN013I-EN-P - March 2022 CompactLogix 5380 Controllers Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintainUser Manual Original Instructions ControlLogix HART Analog I/O Modules Catalog Numbers 1756-IF8H, 1756-IF8HK, 1756-IF8IH, 1756-IF8IHK, 1756-IF16H, 1756-IF16HK, 1756-IF16IH,• The 5069-IA16 module inputs use a shared common. The inputs have a return through internal module circuitry to the SA (–) terminal on the SA Power RTB. • If you install modules in a 5069 Compact I/O system that use AC SA power and DC SA power, you must install them on separate SA Power buses. Summary of Contents for Allen-Bradley 5069-IF8. Page 1 User Manual 5000 Series Analog I/O Modules in Logix5000 Control Systems Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8... Page 2 Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE). Allen-Bradley, Compact I/O, ControlLogix, Integrated ... DDSSep 26, 2022 · 5069-IF8 FieldPowerOff = 1. Got a trouble call with a 5069-IF8 module that has all the channels flashing red. Upon logging in, I see that each channel is faulted with the FieldPowerOff bit set to 1. I had them verify the SA power is good, which it is, and another 5069-IF8 module 2 slots down is functioning fine, so SA power appears to be good. Australian RCM. IECEx Scheme. ATEX. This product was certified with the above certifications as of 2023-09-04. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries. I have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. RickView and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 27 - Module (MOD) Status Indicator - 5069 Compact I/O Analog I/O Modules... Get Support 5069-IF8 Find a Distributor Technical Specifications For full product specifications, please see the product catalog. Documentation Find all available product literature for this product in the Literature Library results.5069-L310ERS2K, 5069-L310ERMS2K, 5069-L320ERS2K, 5069-L320ERMS2K, 5069-L330ERS2K, 5069-L330ERMS2K, 5069-L350ERS2K, 5069-L350ERMS2K Compact GuardLogix 5380 SIL 3 Controller Catalog Numbers 5069-L306ERMS3, 5069-L310ERMS3, 5069-L320ERMS3, 5069-L330ERMS3, 5069-L340ERMS3, 5069-L350ERMS3, 5069-L380ERMS3, 5069-L3100ERMS3 Compact GuardLogix 5380 SIL 3 Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual Original Instructions IMPORTANT This manual has been replaced by the Compact 5000 I/O Analog Modules User Manual, publication 5069-UM005.User Manual Original Instructions ControlLogix HART Analog I/O Modules Catalog Numbers 1756-IF8H, 1756-IF8HK, 1756-IF8IH, 1756-IF8IHK, 1756-IF16H, 1756-IF16HK, 1756-IF16IH,Lifecycle status: ACTIVE. Find a Distributor. to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Register this Product. Add to BoM. Add to Repair Quote. Get Support. 5069-L320ER. Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User Information ControlLogix 8 Point A/I Module. Lifecycle status: ACTIVE. Find a Distributor. Find Product Drawings. Find Firmware & Downloads. Add to BoM. Get Support. 1756-IF8. Find a Distributor.1746-to-5069 I/O Conversion System Installation ... 1746-NO4V 4-Channel Analog I/O Modules User Manual Download. 1746-NI8 Analog Input Module User Manual 2 Rockwell Automation Publication 5069-IN008D-EN-P - December 2021 Compact 5000 Digital 4-point Isolated Relay Digital Output Module Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain Series information for 5069-IF8. For additional information about 5069-IF8 check the data sheet or manual. Also check the manual PDF for all wiring diagrams, compatibility, troubleshooting, specifications, installation instructions, and accessories (such as batteries, terminal blocks, or cables) regarding 5069-IF8.2 Rockwell Automation Publication 5069-IN004D-EN-P - December 2021 Compact 5000 Digital 16-point Sinking Input Modules Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or ...Rockwell Product Catalog. Packaged Solutions (148) Product Selection Wizards (6) Condition Monitoring (10) Condition Sensors, Switches and Controls (19) Connection Systems (13) Control Circuit and Load Protection (81) Drives (70) Hazardous Locations (2) Catalog Number 5069-OA16 The 5069-OA16 digital 16-point AC output module supports 120V AC and 240V AC signals drive output devices. The data that is sent to the module from a controller and the state of some input modules determines the 5069-OA16 module behavior. Compact 5000™ I/O modules use the Producer/Consumer communication model.DDS5069-AENTR, 5069-AENTRK(1) (1) A catalog number followed by a “K” indicates a conformal coating option. 10 Mbps 100 Mbps 1 Gbps Yes Yes Yes No Explicit Implicit Yes 5069-AEN2TR 10 Mbps 100 Mbps 1 Gbps Yes Yes Yes No Not Supported Yes IMPORTANT Protected Mode is only available with the 5069-AENTR adapter. The 5069-AEN2TR adapter does not ...User Manual. Original Instructions. 5000 Series Analog I/O Modules in Logix5000 Control Systems. Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8. Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available.2 Rockwell Automation Publication 5069-IN013I-EN-P - March 2022 CompactLogix 5380 Controllers Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain5069 Compact I/O 16 Channel 24VDC Sink Input Module. Lifecycle status: ACTIVE. Find a Distributor. Learn how to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Add to BoM. Get Support. 5069-IB16. Find a Distributor. Australian RCM. IECEx Scheme. ATEX. This product was certified with the above certifications as of 2023-09-04. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.1 Publication 1769-UM002B-EN-P - July 2005 Summary of Changes The 1769-IF8, -OF8C, and -OF8V modules have been added to this manual since the last printing.I have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. RickThe 5069-IY4 has an input resolution of 15-bits plus sign and 16 bits for voltage; 16-bits for current, RTD and Thermocouple. Is the Thermocouple input provided with CJC sensors? Yes. Two (2) CJC sensors are available. What is the scan time of the 5069-IY4? The 5069-IY4 has rated scan time of 625 µs per channel and 2.5 ms per group.1746-to-5069 I/O Conversion System Installation ... 1746-NO4V 4-Channel Analog I/O Modules User Manual Download. 1746-NI8 Analog Input Module User Manual Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User Information Issue 3: Updated ratings on 5069-IB6F3W and 5069-OF8 to 900mA and 250mA respectively, added models 5069-IA16, 5069-OB8, 5069- OA16 and 5069-OW16 and updated drawings. Issue 4: Update was to clarify the spacings verdict in Clause 13 from the IEC 60079-15 standard. Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available. 2 Rockwell Automation Publication 5069-IN004D-EN-P - December 2021 Compact 5000 Digital 16-point Sinking Input Modules Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or ...Lifecycle status: ACTIVE. Find a Distributor. to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Register this Product. Add to BoM. Add to Repair Quote. Get Support. 5069-L320ER.(1) Catalog numbers 5069-IF8 and 5069-IY4 support differential inputs only. Conversion Module Catalog Number Conversion Module Description 1746-NI8 5069-IF8 1492-CM1746-MO5 High Resolution (8) Analog Input Module 1746-NI4 5069-IY4 1492-CM1746-MO6 High Resolution (4) Analog Input Module Catalog Number 5069-OA16 The 5069-OA16 digital 16-point AC output module supports 120V AC and 240V AC signals drive output devices. The data that is sent to the module from a controller and the state of some input modules determines the 5069-OA16 module behavior. Compact 5000™ I/O modules use the Producer/Consumer communication model.Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User Information(1) Catalog numbers 5069-IF8 and 5069-IY4 support differential inputs only. Conversion Module Catalog Number Conversion Module Description 1746-NI8 5069-IF8 1492-CM1746-MO5 High Resolution (8) Analog Input Module 1746-NI4 5069-IY4 1492-CM1746-MO6 High Resolution (4) Analog Input ModuleAnalog I/O Module Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 High-speed Counter Module Catalog Number 5069-HSC2xOB4 Serial Module Catalog Number 5069-SERIAL Field Potential Distributor Catalog Number 5069-FPD Address Reserve Module Catalog Number 5069-ARM EtherNet/IP Adapter Catalog Number 5069-AENTR, 5069-AEN2TRGet Support 5069-IF8 Find a Distributor Technical Specifications For full product specifications, please see the product catalog. Documentation Find all available product literature for this product in the Literature Library results.

5069-AENTR, 5069-AENTRK(1) (1) A catalog number followed by a “K” indicates a conformal coating option. 10 Mbps 100 Mbps 1 Gbps Yes Yes Yes No Explicit Implicit Yes 5069-AEN2TR 10 Mbps 100 Mbps 1 Gbps Yes Yes Yes No Not Supported Yes IMPORTANT Protected Mode is only available with the 5069-AENTR adapter. The 5069-AEN2TR adapter does not .... Optionpercent3epercent3coptionpercent20value

5069 if8 manual

View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Table 33 - 5069-IY4 Module - Configuration Tags Name Size Definition Chxx.HighSignal REAL One of four points used in...Describes how to install and wire the 5069-IF8 analog input module. 5069 Compact I/O Analog 4-channel Current/Voltage/RTD/Thermocouple Input Module Installation Instructions, publication 5069-IN011 Describes how to install and wire the 5069-IY4 analog input module. 5069 Compact I/O Analog Current/Voltage Output Modules Installation Instructions,5069-IF8: Manufacturer: Allen-Bradley / Rockwell Automation: Description: Allen-Bradley 5069-IF8 5069 Compact I/O 8-Ch Current/Voltage Input Module: Full Description: Allen Bradley 5069-IF8 5069 CompactLogix Compact I/O 8 Channel Current/Voltage Analog Input Module: UPC / GTIN: 00885630530062: Status: Current Product Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User InformationUser ManualOriginal Instructions Compact 5000 I/O Analog Modules Catalog Numbers 5069-IF8, 5069-IY4, 5069-IY4K, 5069-OF4, 5069-OF4K, 5069-OF8 2Rockwell Automation Publication 5069-UM005C-EN-P - January 2022 Compact 5000 I/O Analog Modules User Manual Important User InformationThis manual describes how to install, configure, and troubleshoot your ControlLogix® digital I/O modules. There is also a complete listing of digital input and output modules, including specifications and wiring diagrams. You must be able to program and operate a ControlLogix controller to use your digital I/O module efficiently.2 Rockwell Automation Publication 5069-IN005C-EN-P - December 2021 Compact 5000 High-speed Counter Module Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this ...Summary of Changes This manual contains new and updated information as indicated in the following table. Topic Page Added 5094-IRT8S and 5094-IRT8SXT module information. Throughout. Added topic on Manual Conventions. 10 Added topic on Feature Support. 10 Added Terminology. 10 Added topic on Controller and Software Compatibility. 16 DDSThe 5069-IF8 analog 8-channel current/voltage input module offers non-isolated input channels that can connect to current or voltage input devices. The module supports multiple ranges for each input type. Compact 5000TM I/O modules use the Producer/Consumer communication model. 5069-IF8: Manufacturer: Allen-Bradley / Rockwell Automation: Description: Allen-Bradley 5069-IF8 5069 Compact I/O 8-Ch Current/Voltage Input Module: Full Description: Allen Bradley 5069-IF8 5069 CompactLogix Compact I/O 8 Channel Current/Voltage Analog Input Module: UPC / GTIN: 00885630530062: Status: Current ProductAustralian RCM. IECEx Scheme. ATEX. This product was certified with the above certifications as of 2023-09-04. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries..

Popular Topics