Lincoln sp 125 plus problems - Basic wire welding for projects and repairs around the shop farm or home that where the Weld-Pak 125 HD comes in handy. Plug in the Weld-Pak 125 HD anywhere common 120-Volt input power is available. Set the simple 2 knobs tapped control for your material application and get it done. Right out of the box, the Weld-Pak is set up for gas-less flux ...

 
This item, Lincoln SP-125 Plus Mig Welder, is part of the auction: Town of Hamburg Hwy, NY #14317. Lincoln SP-125 Plus wire feed problem 11-01-2008, 06:59 PM. A good friend of mine was given an old SP-125 that wasn’t quite working right. He replaced the gun, but now that I’m back I’ve checked it out and here’s the issue.. Dte

VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.This item, Lincoln SP-125 Plus Mig Welder, is part of the auction: Town of Hamburg Hwy, NY #14317. Lincoln SP-125 Plus wire feed problem 11-01-2008, 06:59 PM. A good friend of mine was given an old SP-125 that wasn’t quite working right. He replaced the gun, but now that I’m back I’ve checked it out and here’s the issue.Dec 30, 2019 · The Lincoln SP 125 is 120 volt and uses a 20 amp breaker. That is a problem with 120 volt welders. 1) see can change the welder to 240 volt some Lincoln welder can be changed. 2) I fix by buying a 240 volt welder. 3) cheat use a 30 amp breaker some will use the dryer breaker in the garage. SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantTips Nozzle Diffuser Liner fits Lincoln SP-135 Plus SP-135T MIG Welder ILS 41.80 to ILS 121.66 Tips Nozzle Diffuser Liner fits Lincoln SP-85 SP-100 SP-100-I SP-100T MIG WelderThere seems to be a problem serving the request at this time. breadcrumb. ... $125.00. $10.25 shipping. or Best Offer. ... New Listing Lincoln Welder Parts L10952-2BO ...Nov 1, 2008 · I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two. 02-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.SP-135 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantScrewing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool.Your #1 Source for Lincoln welder parts on the internet. Choose a link Below. I Know My Part Number; I would like to find the Part Number; I would like to Call or E-mail. Allow 7-10 Day on all Ground orders under $99. All orders over $99 will Ship 3-4 days. If you need Special Shipping please give us a call at 866-922-8147.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 1302-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.lincoln sp-125 plus; idealarc 250/250; any one know where i can get a manuale for this; Couple of sa200 questions; Opportunity to pick up a Lincoln 175 for $175, good deal? Help with PrecisionTig 275 Advanced Panel Install; Will spool gun work with Wire-Matic 255 Mig; Lincoln Invertec V350-Pro w/ pulse. K1728-7; Lincoln DC 250 MK Arc Welder(55) 55 product ratings - Lincoln SP-180T Mig Welder 220V Recondition 180 Amps Welds Flux Core or Gas $700.00 Trending at $762.50 eBay determines this price through a machine learned model of the product's sale prices within the last 90 days.It started humming and blowing breakers so i did the research and tested the diodes. They failed. People are saying to replace all of them at same time because if one fails then it usually takes out the other. i found the 9sm9661-39 and 9sm9661-39r diodes online but they are running like 50 each. i remember while searching for a cheaper option ...Scott you did notice though that I cast a vote for the SP 135 over the MM 135. Untill Miller decides to change the variable voltage with wire speed tracking idea the Lincioln will be the leader between the two. MigMaster 250 - Smooth arc with a good touch of softness to it. Good weld puddle wetout.To start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...There seems to be a problem serving the request at this time. breadcrumb. ... $125.00. $10.25 shipping. or Best Offer. ... New Listing Lincoln Welder Parts L10952-2BO ...Lincoln Powermig 255. $2,200. Mount Vernon Triumph 2 & 4 Post Lifts, Low Price, Free Shipping, No Tax!!! $115. 0% 12 month Financing!!! Call or Text (866)774-7743New listings: Lincoln SP-100 wire welder - $225 (Clarence), Lincoln Electric Welder SP-125 Plus 120 Volt - $275 (ELKHART) POST AD FREE. Free Local Classifieds .It works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.33 Post Thanks / Like Lincoln SP-125 - Not feeding wire I have a Lincoln SP-125 (just picked up used) that is now not feeding wire. The unit turns on, fan starts, and when you pull the trigger you hear a click as if it wants to feed, but nothing. I checked the poles on the drive motor and it does not appear that there is any voltage... Ideas?Home › SP-125 PLUS HTP Replacement Gun & Parts SP-125 PLUS HTP Replacement Gun & Parts HTP America® MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.Ad id: 3012175658160591. Views: 3523. Price: $379.00. LINCOLN 125 MIG WELDER. AS NEW CONDITION, LESS THAN ONE HOUR USE. 120V. WELDS UP TO 1/4 INCH STEEL WITH FLUX CORE WIRE. Report. Last Updated on: August 30, 2023 with LINCOLN 125 MIG WELDER SP 125 PLUS - $379 (NASSAU)Your #1 Source for Lincoln welder parts on the internet. Choose a link Below. I Know My Part Number; I would like to find the Part Number; I would like to Call or E-mail. Allow 7-10 Day on all Ground orders under $99. All orders over $99 will Ship 3-4 days. If you need Special Shipping please give us a call at 866-922-8147.Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.Wire question for the Lincoln SP-125+. By Date 01-25-2008 06:23. I bought an unused Lincoln SP-125 Plus MIG machine. It can run .023 / .025 / .030 Hardwires and .035 Flux-core (Innershield). The machine shows you can run all of those diameter wires with the existing drive rollers, but you can also purchase the optional knurled rollers for the ...Lincoln 175 or Miller 175 would be my choice, they only cost about $200 more than a 135. If 220V is a problem for you (and you don't have a dryer outlet near by) check some of the dual voltage machines like the Miller DVI. 1965 Scout 80 7.3PSD/ZF/203/205 D60F/14BFF. Member: 4 Jackstand Wheeler's Association.You need to blow out your cable liner, while your doing this make sure your contact tip is clean and unobstructed. Also make sure that your drive roll tension is not to much, enough to move the wire but not enough to push it when you have the wire held at the gun.Cleanliness in a wirefeed insures problem free usability. Good luck.LB.33 Post Thanks / Like Lincoln SP-125 - Not feeding wire I have a Lincoln SP-125 (just picked up used) that is now not feeding wire. The unit turns on, fan starts, and when you pull the trigger you hear a click as if it wants to feed, but nothing. I checked the poles on the drive motor and it does not appear that there is any voltage... Ideas?One sure sign is if the wire burns back in the contact tip. That could mean about 10 different things. Is this what is happening. John. SMAW,GMAW,FCAW,GTAW,SAW,PAC/PAW/OFC. and Shielding Gases.Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. Lincoln Electric: Forney: Lincoln Electric: Name: 120-Volt 140 Amp Easy Weld FC-i Flux Core Gasless Welder: 125 Amp Weld-Pak 125 Flux-Core Wire Feed Welder, 115V (No Gas) 140 Amp 120-Volt MIG Welder: Weld-Pak 180 Amp MIG Flux-Core Wire Feed Welder, 230V, Aluminum Welder with Spool Gun sold separately: Price $CHANGING DRIVE ROLL The SP-100 Wire Feed Drive Roll (1 ) has two grooves; one for 0.023” – 0.025” (0,6 mm) solid steel electrode and the other for 0.030” (0,8 mm) solid and 0.035” (O,9 mm) flux-cored steel electrode. Page 28 9. Screw the gas diffuser onto the end of the gun tube and securely tighten. 10.One sure sign is if the wire burns back in the contact tip. That could mean about 10 different things. Is this what is happening. John. SMAW,GMAW,FCAW,GTAW,SAW,PAC/PAW/OFC. and Shielding Gases.Start with the drive roll pressure very loose. Increase the pressure only until it is very difficult to stop the wire from feeding out of the contact tip. Use a pliers or block of wood to try and stop the wire from feeding. Go perhaps one-half of a turn beyond this point.Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool.Mar 23, 2017 · Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine. 1 Post Thanks / Like Replacing Diodes on Lincoln sp125 plus. 20 plus yrs of use I cant send it to scrap Well Ive already picked up an Amico 140 welder off home depots website and its not too bad for the price. Its not as adjustable as my 125 plus. I can lay a damn nice bead with the old lincoln.VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.Ad id: 3012175658160591. Views: 3523. Price: $379.00. LINCOLN 125 MIG WELDER. AS NEW CONDITION, LESS THAN ONE HOUR USE. 120V. WELDS UP TO 1/4 INCH STEEL WITH FLUX CORE WIRE. Report. Last Updated on: August 30, 2023 with LINCOLN 125 MIG WELDER SP 125 PLUS - $379 (NASSAU)926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.I will address a feed problem I have with my Lincoln 256 Power Mig welder. The problem is erratic feeding of the wire while welding. This problem started fro...125 Amp 115-Volt Weld-Pak 125 HD Flux-Cored Wire Welder with .035 in. Flux-Core Welding Wire (1 lb. Spool) Whether you're working in the shop, on the Whether you're working in the shop, on the farm or at home, the Flux-Cored Welder is your go-to tool for basic wire welding projects and repairs. Simply plug in the welder where 120-Volt input ...Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine.There seems to be a problem serving the request at this time. breadcrumb. ... $125.00. $10.25 shipping. or Best Offer. ... New Listing Lincoln Welder Parts L10952-2BO ...I was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.Lincoln Powermig 255. $2,200. Mount Vernon Triumph 2 & 4 Post Lifts, Low Price, Free Shipping, No Tax!!! $115. 0% 12 month Financing!!! Call or Text (866)774-7743Home › SP-125 PLUS HTP Replacement Gun & Parts SP-125 PLUS HTP Replacement Gun & Parts HTP America® MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.It doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power.VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.I was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.33 Post Thanks / Like Lincoln SP-125 - Not feeding wire I have a Lincoln SP-125 (just picked up used) that is now not feeding wire. The unit turns on, fan starts, and when you pull the trigger you hear a click as if it wants to feed, but nothing. I checked the poles on the drive motor and it does not appear that there is any voltage... Ideas?Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantI have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant#1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened.SP-125 PLUS ORDER FORM DISTRIBUTED BY: THE LINCOLN ELECTRIC COMPANY Local Sales and Service through Global Subsidiaries and Distributors Cleveland, Ohio 44117-1199 U.S.A TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com Wire Feeder / Welders E7.20 3/00 PRODUCT DESCRIPTION ORDER NUMBER QUANTITY PRICE SP-125 Plus K660-3 ...Find many great new & used options and get the best deals for Lincoln Electric Sp-125 Plus Wire Feed MIG Suitcase Welder at the best online prices at eBay! Free shipping for many products!I have a Lincoln 135 Pro that I use all the time for sheetmetal. Works great, on the smaller stuff no problem. If you have the power, and the dough, go bigger, but if you have a 1927 house like me, with 120 wiring, its a good machine. When I upgrade my power, I will get a bigger machine for heavier stuff. flatheadhero, Mar 19, 2007.SP-135 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantIt works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.Product Names and Code Numbers can be found on the name plate of welders and wirefeeders. In order to ensure you have the correct Operator's Manual for your machine you must use a Code Number Search.Lincoln Electric: Forney: Lincoln Electric: Name: 120-Volt 140 Amp Easy Weld FC-i Flux Core Gasless Welder: 125 Amp Weld-Pak 125 Flux-Core Wire Feed Welder, 115V (No Gas) 140 Amp 120-Volt MIG Welder: Weld-Pak 180 Amp MIG Flux-Core Wire Feed Welder, 230V, Aluminum Welder with Spool Gun sold separately: Price $I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250.SP-125 PLUS ORDER FORM DISTRIBUTED BY: THE LINCOLN ELECTRIC COMPANY Local Sales and Service through Global Subsidiaries and Distributors Cleveland, Ohio 44117-1199 U.S.A TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com Wire Feeder / Welders E7.20 3/00 PRODUCT DESCRIPTION ORDER NUMBER QUANTITY PRICE SP-125 Plus K660-3 ...1 Post Thanks / Like Replacing Diodes on Lincoln sp125 plus. 20 plus yrs of use I cant send it to scrap Well Ive already picked up an Amico 140 welder off home depots website and its not too bad for the price. Its not as adjustable as my 125 plus. I can lay a damn nice bead with the old lincoln.Conical Nozzle, 3-Pack, f/Tweco® Mini MIG & Tweco® #1 Style MIG Welding GunsIf you have any problems with the registration process or your account login, please contact support. Results 1 to 1 of 1 Thread: MIG Welder for Sale - Lincoln SP-125 PlusI have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.Lincoln Electric. $118.81 ) +Free Shipping. SKU: S24355-4. Quantity: Decrease Quantity: Increase Quantity: Only left in stock! Adding to cart… category.add_cart ...Product Names and Code Numbers can be found on the name plate of welders and wirefeeders. In order to ensure you have the correct Operator's Manual for your machine you must use a Code Number Search.If you have any problems with the registration process or your account login, please contact support. Results 1 to 2 of 2 ... Lincoln SP 125 plusLincoln SP-125 Plus Wire Feed Welder with Torch, Ground Clamp, Cart and More. LOT No: 142 Category: Welding Equipment. All Auction Items. Server time---buyer premium ...lincoln sp-125 plus; idealarc 250/250; any one know where i can get a manuale for this; Couple of sa200 questions; Opportunity to pick up a Lincoln 175 for $175, good deal? Help with PrecisionTig 275 Advanced Panel Install; Will spool gun work with Wire-Matic 255 Mig; Lincoln Invertec V350-Pro w/ pulse. K1728-7; Lincoln DC 250 MK Arc WelderLincoln Electric® Input Cord is designed to use with SP-125 plus welding system. We use cookies to improve your browsing experience and help us improve our websites. By continuing to use our website, you agree to our use of such cookies.This item, Lincoln Electric SP-125 Plus, is part of the online auction: H & L Steel Erectors - Complete Sellout - Construction Equipment & Tools.Basic wire welding for projects and repairs around the shop farm or home that where the Weld-Pak 125 HD comes in handy. Plug in the Weld-Pak 125 HD anywhere common 120-Volt input power is available. Set the simple 2 knobs tapped control for your material application and get it done. Right out of the box, the Weld-Pak is set up for gas-less flux ...926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.(55) 55 product ratings - Lincoln SP-180T Mig Welder 220V Recondition 180 Amps Welds Flux Core or Gas $700.00 Trending at $762.50 eBay determines this price through a machine learned model of the product's sale prices within the last 90 days.Problem it's will be great for tack welds only.There was a guy doing production aluminum back in the day, The SP-125 is a nice auto-body rig, and exhaust type work. A machine like a Klutch 140si with spool-gun is light years ahead of the Lincoln in laying beads down..I would like to have a SP-125/135 in my shop.You need to blow out your cable liner, while your doing this make sure your contact tip is clean and unobstructed. Also make sure that your drive roll tension is not to much, enough to move the wire but not enough to push it when you have the wire held at the gun.Cleanliness in a wirefeed insures problem free usability. Good luck.LB.My second , a Lincoln SP125 Plus, lots of years ago. Use it weekly. I mainly do body panel rust repair on vintage sports cars, ie thicker carbon steel. My son is 50 miles away with projects too. I need to stage a welder there. I liked my welder so much I found one like it for him, but it needs some parts. I know Lincoln did't make it.I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250.Re: sp 125 plus and aluminum. FYI I use a regular push gun on aluminum. I am taking a lunch break and going out to weld more of it. A teflon liner is a must. Use 5356 wire 4043 is to soft trust me I have a roll in mine right now. The cable must be kept as strait as posible and dont twist it.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 13

Re: sp 125 plus and aluminum. FYI I use a regular push gun on aluminum. I am taking a lunch break and going out to weld more of it. A teflon liner is a must. Use 5356 wire 4043 is to soft trust me I have a roll in mine right now. The cable must be kept as strait as posible and dont twist it.. Www..t mobilesettlement.com

lincoln sp 125 plus problems

Lincoln ElectricLincoln Electric L-5254 Circuit Board L5254. $149.99 New. MILLER ELECTRIC 240978 USER INTERFACE MODULE CONTROL PANEL. $1,350.00 New.No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...1 Post Thanks / Like Replacing Diodes on Lincoln sp125 plus. 20 plus yrs of use I cant send it to scrap Well Ive already picked up an Amico 140 welder off home depots website and its not too bad for the price. Its not as adjustable as my 125 plus. I can lay a damn nice bead with the old lincoln.Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. 1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.I had two mm130 one was a 130 xp. I would say a fair comparison would be to a Lincoln sp 125 plus. The cost was about even ($500.00 new) The MM 130 was really not much of a welder but the xp version could more then hold it's own with the 125 Lincoln. I prefer the MM 130 xp over the new MM 135, My XP came with the Hobart OXO gun, that was really ...02-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.Tips Nozzle Diffuser Liner fits Lincoln SP-135 Plus SP-135T MIG Welder ILS 41.80 to ILS 121.66 Tips Nozzle Diffuser Liner fits Lincoln SP-85 SP-100 SP-100-I SP-100T MIG WelderLincoln Electric L-5254 Circuit Board L5254. $149.99 New. MILLER ELECTRIC 240978 USER INTERFACE MODULE CONTROL PANEL. $1,350.00 New.1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.Ideal replacement for Lincoln Magnum 100L (K530-6). Usually, Lincoln Magnum 100L (K530-6) MIG gun can be found on SP-140T/180T, MIG-Pak 140/180, ProMIG 140/180, Weld-Pak 125HD/140HD/180HD, Power MIG 140C/180C and EasyCore 140/180, etc. welders. Use standard front consumables 21 series nozzle, 11 series tip and xx-40-15 liner.I just bought a lincoln sp 125 for $200 I havent seen it yet my grandpa got it and he is on his way home now he says it is in very good condition. I know it will not weld much at all but I figure I can use it for small projects and tacking. Then when I get money I will get a mm210.Product Names and Code Numbers can be found on the name plate of welders and wirefeeders. In order to ensure you have the correct Operator's Manual for your machine you must use a Code Number Search.To start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...To start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...1994 lincoln town car. radio and power antenna don't work. fuses are good everything else works. what is the problem? ... lincoln sp 125 plus glowworm 30 cxi ...1994 lincoln town car. radio and power antenna don't work. fuses are good everything else works. what is the problem? ... lincoln sp 125 plus glowworm 30 cxi ...Wire welder feed, but no arc (spark) 10-20-2012, 08:43 PM. I have a millermatic 150 that I bought used a few years ago. It has been an amazing welder. I was welding the other day and in the middle of a bead, it stopped welding. I have had this happen before and waited to let it cool and continued on..