Richmond water heater pilot light won - Usually, the pilot light isn’t staying lit on a Richmond water heater due to the bad thermocouple. It may also be due to a lack of combustible air, but this is less likely. Look to see if the thermocouple has been bent, damaged, or is too dirty, and take appropriate action.

 
It's easy to fix this water heater problem by yourself. I fixed mine and also decided to make a better video to help out more people who love DIY.- Pilot lig.... Plague

A water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ...Mar 20, 2022 · The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article. Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to tryMar 1, 2010 · hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty. May 5, 2022 · I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m … It's not always the thermocouple that is faulty. Many of these gas control valves can be easily fixed!! This is a very quick fix that anyone can do without c...Mar 8, 2010 · Begin by turning your pilot light off, if it is not already. Next, turn off the flow of gas to your furnace completely using the shutoff valve. It should be nearby or even on your furnace. Once you have done this, allow your furnace to cool down for at least 30 minutes so it is safe to open, then open the hatch covering your pilot light and ... If your gas water heater doesn’t stay lit, you may have a defective thermocouple. Most gas fired water heaters use a standing pilot to ignite the main burner. The gas for the pilot assembly is supplied by the main gas valve and is monitored by the thermocouple. The thermocouple is a heat sensing probe that is part of the pilot assembly and ...Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … read moreMay 5, 2022 · I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m … It is able to detect flammable vapors, protecting the water heater from excessive electricity flow and damage. In case the water heater pilot light doesn’t stay lit, it is possible that the thermal switch is either damaged or tripped. 3. Faulty thermocouple. Even if you’ve replaced the thermocouple, it is still possible that the ...Dec 22, 2022 · Here are the steps to follow: Turn off the gas supply: Locate the gas valve on your water heater and turn it to the “off” position. This will prevent gas from flowing to the pilot light while you work on it. Wait for the water heater to cool down: Give the water heater enough time to cool down before you start working on it. My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won’t stay lit after releasing button. The gas tank ran out of gas and was refilled. It is a sealed system with a window to view the pilot light.Dec 31, 2015 · 2. If I understand correctly, your pilot flame is lighting correctly. But the main burner won't turn on because the electronics in the Gas Control Valve don't acknowledge the pilot is lit. There are two likely faults: Thermopile is not sensing the flame correctly, or. Circuit Board in the Gas Control Valve is defective. The Solution: Straighten all kinks on the flex tube. It’s also wise to look for any visible damage that might cause gas leaks. Gas leaks will reduce the amount of gas reaching the burner. It might be the reason why your furnace pilot light keeps going out or flickering. 6. A Faulty Main Control Valve.Sep 14, 2022 · 1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve. Press and hold down on the gas control knob, or pilot set button. At the same time as you’re holding down the pilot switch, press on the piezo igniter. When you click the igniter, you should hear a “click” sound, indicating the spark igniting the pilot. Once the pilot light is on, continue pressing down on the pilot switch for a minute to ...We have a Rheem gas water heater model number 21V40-7P. We've just gotten the gas tank refilled, but for some reason, the pilot light went out this morning and the water heater is leaking. I'm trying … read more5. Energize The Gas Valve. Confirm that the pilot is lit visually. Continue holding the gas supply button for around 45 seconds to heat the thermocouple.Let the button go, and if the pilot stays lit, you are ready to turn ON the gas control knob.Jul 29, 2023 · Richmond Water Heater Pilot Light Won’t Stay Lit: A Detailed Discussion. As you can see from the table above, there are many reasons why the heater’s pilot light tends not to stay lit. And there are solutions for each problem. In the following part, I have discussed the issues in more detail and also shared how you can solve them. Mar 20, 2022 · The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article. My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won’t stay lit after releasing button. The gas tank ran out of gas and was refilled. It is a sealed system with a window to view the pilot light.By Vikram May 7, 2023 If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won’t stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them.I'm not a professional. This is the one thing that's worked AMAZING to get my hot water heater pilot light to stay on! INCREDIBLE prices on AMAZON: https://a...If the pilot won't stay lit after you release the button/knob you hold down to light it then the first thing that needs to be done is to replace the pilot flame sensor, thermocouple (heavy bare copper wire connected to the gas valve) or the thermopile (small shielded cable with 2 wires connected to the gas valve).Meet the Most Efficient Water Heater Available Richmond Hybrid Electric Water Heaters Learn More ... Most efficient water heater available – with up to $5,000 in ...Aug 8, 2018 · My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won’t stay lit after releasing button. The gas tank ran out of gas and was refilled. It is a sealed system with a window to view the pilot light. I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.Reopen the shutoff valve. Relight the pilot light. Turn the control valve to “on”. When the gas burner comes on, use a 50/50 dish soap/water mix to test the screw joints for air bubbles that indicate leaks. Note: When relit, the water heater pilot light flame should wrap around the thermocouple bulb.Usually, the pilot light isn’t staying lit on a Richmond water heater due to the bad thermocouple. It may also be due to a lack of combustible air, but this is less likely. Look to see if the thermocouple has been bent, damaged, or is too dirty, and take appropriate action.A water heater pilot lights but not the burner if the thermostat is damaged or over 10 years old. Flame sensors can fail if they are dislodged and the burner won’t detect the pilot light’s flame. Your water heater’s burner won’t work if the gas valve is damaged or the thermostat is unresponsive. Water heater problems often require ...A water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ...Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup the …Jun 10, 2022 · It's not always the thermocouple that is faulty. Many of these gas control valves can be easily fixed!! This is a very quick fix that anyone can do without c... My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won’t stay lit after releasing button. The gas tank ran out of gas and was refilled. It is a sealed system with a window to view the pilot light.07. Blocked Air Intake End-Note Richmond Water Heater Pilot Light Won’t Stay Lit [7 Easy Solutions] Your Richmond Water Heater pilot light won’t stay lit due to several reasons. These include a bad thermocouple, a tripped limit switch, plugged flammable vapor sensor, and a faulty gas valve.Dec 22, 2022 · Here are the steps to follow: Turn off the gas supply: Locate the gas valve on your water heater and turn it to the “off” position. This will prevent gas from flowing to the pilot light while you work on it. Wait for the water heater to cool down: Give the water heater enough time to cool down before you start working on it. Oct 22, 2020 · If the pilot won't stay lit after you release the button/knob you hold down to light it then the first thing that needs to be done is to replace the pilot flame sensor, thermocouple (heavy bare copper wire connected to the gas valve) or the thermopile (small shielded cable with 2 wires connected to the gas valve). Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out.Mar 8, 2010 · Begin by turning your pilot light off, if it is not already. Next, turn off the flow of gas to your furnace completely using the shutoff valve. It should be nearby or even on your furnace. Once you have done this, allow your furnace to cool down for at least 30 minutes so it is safe to open, then open the hatch covering your pilot light and ... I'm not a professional. This is the one thing that's worked AMAZING to get my hot water heater pilot light to stay on! INCREDIBLE prices on AMAZON: https://a...Mar 20, 2022 · The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article. Step 03 – Drain The Tank. Before taking off the gas valve, you need to drain the water heater. Otherwise, you’ll end up with a mess on your hands. The hot water can also cause scalding. Turn off the cold water shutoff valve if you can locate it or shut off the water supply to your entire house.The pilot light is an essential part of your Rheem water heater. If it goes out, your water heater wont provide any heat because the pilot light wont ignite the gas to power the heater. This means that you wont be able to light your pilot light. One potential cause of this issue is that you have a blocked gas line.Pilot light won’t stay lit I had the same problem and placed a small fan in the attic next to the water heater 3 weeks ago and it’s worked so far, Temps in Houston in July are way above 100 degrees in the attic and the problem seems to occur when the outdoor temps are in the mid to high 90’s.01 - Water Heater Gas Valve and Thermostat Assembly. The gas valve opens to allow gas to enter the burner. If the gas valve does not open, the burner will not light. First, ensure that the ignition source is working properly. Second, ensure that the gas valve has pressure. If the ignition source is working, and the gas valve has pressure ...Apr 9, 2020 · I'm not a professional. This is the one thing that's worked AMAZING to get my hot water heater pilot light to stay on! INCREDIBLE prices on AMAZON: https://a... I used this to repair my 40Gal Richmond LP water heater model 6G40-32PF1. The replacement gasket and mounting seal are superior that the one that came with the heater itself. The line lengths provided were more than enough to remount on my water heater.It is able to detect flammable vapors, protecting the water heater from excessive electricity flow and damage. In case the water heater pilot light doesn’t stay lit, it is possible that the thermal switch is either damaged or tripped. 3. Faulty thermocouple. Even if you’ve replaced the thermocouple, it is still possible that the ...I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote.If your Richmond water heater pilot light won’t stay lit, you will have trouble getting hot water around the house. So the first thing you should do is check the thermocouple. But if the thermocouple is fine, you should check the other things I mentioned in today’s article.5. Flex Tube Defects. This also another possible reason why your pilot’s light won’t come on. The flex tube is how the gas reaches the device, and if the continuous flow of gas is interrupted, the pilot light won’t stay lit. This usually happens when the tube is kinked at one or many points.Apr 12, 2021 · 6. Below is a picture of the lighting instructions for your water heater taken from Rheem's website. Make sure to follow the lighting instructions carefully and do not skip any steps. This same instruction set should be available as a sticker on your unit. It looks like you do in fact have to depress the knob in order to turn it so avoid using ... The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ...If the water heater pilot light will not stay lid there are two main options, the first one is the Thermocouple, but if this one is working fine and you can ...Richmond water heater, pilot light won’t remain on, 6G40-36F1, Yesterday - pilot went out, relighted the pilot, pilot - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website.A thermocouple is a function on your water heater that senses the heat on the pilot light and allows gas to flow to the burner. A bad thermocouple will shut off gas to both the pilot and the burner, which is when people notice that the water heater pilot light is out. Your water heater pilot light works in concert with other parts.I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m …Sep 14, 2022 · 1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve. Head down to the water heater to check the pilot and relight it. But first, learn the basics here. By Glenda Taylor and Bob Vila | Updated Sep 23, 2020 9:57 AMPilot light won’t stay lit I had the same problem and placed a small fan in the attic next to the water heater 3 weeks ago and it’s worked so far, Temps in Houston in July are way above 100 degrees in the attic and the problem seems to occur when the outdoor temps are in the mid to high 90’s.If your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ...Aug 8, 2018 · My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won’t stay lit after releasing button. The gas tank ran out of gas and was refilled. It is a sealed system with a window to view the pilot light. Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air ConditioningI have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote.Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out.Mar 8, 2010 · Begin by turning your pilot light off, if it is not already. Next, turn off the flow of gas to your furnace completely using the shutoff valve. It should be nearby or even on your furnace. Once you have done this, allow your furnace to cool down for at least 30 minutes so it is safe to open, then open the hatch covering your pilot light and ... The Richmond Marathon ® water heater offers a LIFETIME warranty. The Marathon is a special water heater that has a seamless blow molded polybutene inner tank. It will not rust. The several inches of foam insulation give it up to 0.93 uniform energy factor. Tank sizes range from 15 gallons to 105 gallons to fit any household need.hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty.If the water heater pilot light will not stay lid there are two main options, the first one is the Thermocouple, but if this one is working fine and you can ... Sep 14, 2022 · 1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve. Jan 26, 2022 · Are you running out of hot water or your hot water is only lukewarm? The most common problem which can be easily fixed is your pilot light went out if you h... It is able to detect flammable vapors, protecting the water heater from excessive electricity flow and damage. In case the water heater pilot light doesn’t stay lit, it is possible that the thermal switch is either damaged or tripped. 3. Faulty thermocouple. Even if you’ve replaced the thermocouple, it is still possible that the ...5. Flex Tube Defects. This also another possible reason why your pilot’s light won’t come on. The flex tube is how the gas reaches the device, and if the continuous flow of gas is interrupted, the pilot light won’t stay lit. This usually happens when the tube is kinked at one or many points.Head down to the water heater to check the pilot and relight it. But first, learn the basics here. By Glenda Taylor and Bob Vila | Updated Sep 23, 2020 9:57 AMHave you tried cleaning/replacing your thermocouple and still no dice? Have you tried cleaning/replacing the pilot assembly and still nothing? My opinion is ...No hot water? If the pilot flame in your water heater keeps on going out or won't stay lit, then it could be a problem with the thermocouple or thermal cutof...If your gas water heater doesn’t stay lit, you may have a defective thermocouple. Most gas fired water heaters use a standing pilot to ignite the main burner. The gas for the pilot assembly is supplied by the main gas valve and is monitored by the thermocouple. The thermocouple is a heat sensing probe that is part of the pilot assembly and ...Reignite the pilot light. Richmond gas heaters use a pilot light to ignite the gas heating the water. Make sure the light hasn't blown out, and if it has, use the ignition mechanism on the heater to light the pilot. Drain and clean the heater. Follow the instructions in Section 2 for draining your Richmond heater and clean the tank and all ... It’s also a relatively inexpensive component. So, you won’t have to break the bank to replace it. You can check out our guide on why Richmond water heater pilot light won’t stay lit where we have broken down how to replace the thermocouple in nice and easy steps. 6. Faulty Pressure SwitchRichmond water heater, pilot light won’t remain on, 6G40-36F1, Yesterday - pilot went out, relighted the pilot, pilot - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website.A water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ...Oct 22, 2020 · If the pilot won't stay lit after you release the button/knob you hold down to light it then the first thing that needs to be done is to replace the pilot flame sensor, thermocouple (heavy bare copper wire connected to the gas valve) or the thermopile (small shielded cable with 2 wires connected to the gas valve). The Richmond Marathon ® water heater offers a LIFETIME warranty. The Marathon is a special water heater that has a seamless blow molded polybutene inner tank. It will not rust. The several inches of foam insulation give it up to 0.93 uniform energy factor. Tank sizes range from 15 gallons to 105 gallons to fit any household need. Feb 9, 2022 · Depending on the water heater you have, it may use an igniter to ignite the gas.When you hold down the pilot switch on a gas heater and click the igniter button repeatedly, a small spark should ignite the pilot.However, if the pilot flame will not light after you click the igniter, you need to verify that a spark is happening inside the pilot.When the piezo igniter is pressed down and released ...

The pilot light is an essential part of your Rheem water heater. If it goes out, your water heater wont provide any heat because the pilot light wont ignite the gas to power the heater. This means that you wont be able to light your pilot light. One potential cause of this issue is that you have a blocked gas line.. H and h gun range

richmond water heater pilot light won

Richmond water heaters have a warranty that is specific to your water heater. The warranty varies based on the model. Some models, like the Marathon, have lifetime warranties, while others have a 6- or even a 12-year warranty.hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty.Sep 25, 2021 · Have you tried cleaning/replacing your thermocouple and still no dice? Have you tried cleaning/replacing the pilot assembly and still nothing? My opinion is ... Richmond water heaters have a warranty that is specific to your water heater. The warranty varies based on the model. Some models, like the Marathon, have lifetime warranties, while others have a 6- or even a 12-year warranty.Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to tryThe water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ... It is more than likely some kind of high limit sensor which would kick the pilot out should the water heater overheat. If your pilot is not staying lit with a new thermocouple, it may be this sensor. Try jumping the 2 leads going to the thermocouple adapter and see if it remains lit. If it does, it is this sensor that is bad.For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater; Durable construction for long life May 5, 2022 · I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m … 01 - Water Heater Gas Valve and Thermostat Assembly. The gas valve opens to allow gas to enter the burner. If the gas valve does not open, the burner will not light. First, ensure that the ignition source is working properly. Second, ensure that the gas valve has pressure. If the ignition source is working, and the gas valve has pressure ...No hot water? If the pilot flame in your water heater keeps on going out or won't stay lit, then it could be a problem with the thermocouple or thermal cutof...Power Vent. Uses indoor air for combustion with flexible venting options up to 100 feet. View Product. Gas. Electric. Speciality. Meet the Most Efficient Water Heater Available Richmond Hybrid Electric Water Heaters Learn More ... Most efficient water heater available – with up to $5,000 in ...So I have a 40 gal Richmond power vent lp water heater. Problem is it doesn't restart So far I have replaced the igniter .I took out the whole water heat and cleaned out the combustion chamber and …A.O. Smith GVR 40 101 water heater had no spark on the pilot. Disassembled and cleaned the pilot light and thermocouple. Reassembled and fired it up on the f...Clean those first before doing anything else. It's routine maintenance that needs to be done in any case. You need to remove the pilot burner, take the pilot tubing off and remove the pilot orifice. Sometimes you can clean the pilot orifice with the wire from a wire brush. Use a wire brush to clean the pilot burner.The pilot light is an important part of your Rheem water heater, but it might occasionally not light. Usually, relighting the light will restore your water heater’s functionality, but if the light won’t light, there’s a larger issue to address. Contents show 1 1. You Have a Blocked Gas Line 1.1 How To Fix 2 … Rheem Water Heater Pilot Light Won’t Light – Fixed Read More »Reignite the pilot light. Richmond gas heaters use a pilot light to ignite the gas heating the water. Make sure the light hasn't blown out, and if it has, use the ignition mechanism on the heater to light the pilot. Drain and clean the heater. Follow the instructions in Section 2 for draining your Richmond heater and clean the tank and all ... The pilot on my Rheem furnace will not stay lit. I have replaced the thermocouple to no avail. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly.Replace the pilot assembly, I do water heater repair, that unit is actually made by A.O. Smith. It’s got a 180 pilot assembly. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete.Water heater pilot won't light. Richmond water heater, smelled for gas at end of tibe by burner and is present. Filter isn't clogged. Ignition sparks. ....